Manifolds
10 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C |
This manifold is only for zero-point / equalization of an differential pressure gauge. The connections and the connection-measures can be adjusted to the differential pressure gauge. | Details |
21 |
DN: max 5 (8) |
This 2 valve manifold has an isolation and a vent / calibration valve. | Details |
s. also Bar-stock manifold 27/28. |
22 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C |
This 2 valve manifold is for direct mounting to a pressure transmitter. The inlet and test /calibrate connections are separately shut off. Additionally this manifold has test and / or blow-out connection. | Details |
s. also Bar-stock manifold 27/28. |
30 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C (T max 530°C with external spindle thread) |
This 3 valve manifold is designed for remote mounting to a transmitter. It has two block valves (+ and - lines) and an equaliser valve. | Details |
31 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C (T max 450°C with external spindle thread) |
This 3 valve manifold has an isolation-, an instrument- and a vent/calibrate valve. | Details |
33 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C (T max 450°C with external spindle thread) |
This 3 valve manifold is designed for remote mounting to a transmitter. It has two blockvalves (+ and - lines) and an equaliser valve. The manifold could have optional proof- and / or blow out connections. |
Details |
35 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C |
This 3 valve manifold is designed for direct mounting to a transmitter. It has two block valves (+ and - lines) and an equaliser valve. |
Details |
s. also Bar-stock manifold 37. |
36 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C |
This 3 valve manifold is designed for remote mounting to a transmitter. It has two blockvalves (+ and - lines) and an equaliser valve. The manifold could have optional proof- and / or blow out connections. |
Details |
51 |
DN: max 5 (8) |
This 5 valve manifold is designed for remote mounting to a transmitter. It has two block valves (+ and - lines), 2 proof vaives and an equaliser valve. |
Details |
s. also Bar-stock manifold 51. |
58 | DN: max 5 (8) PN max. 420 (6000psi) T max 250°C |
This manifold is only for zero-point / equalization of an differential pressure gauge. The connections and the connection-measures can be adjusted to the differential pressure gauge. |
Details |
s. also Bar-stock manifold 57. |
73 |
DN: max 5 Ausblasventil DN8 |
To this 5 valve manifold a transmitter will be directly flanged. The manifold has two block valves (+ and - lines), 2 blow out valves and an equaliser valve. For use in power plants. |
Details |
75 |
DN: max 5 Ausblasventil DN8 |
To this 5 valve manifold a transmitter will be directly flanged. The manifold has two block valves (+ and - lines), 2 blow out valves, 2 test connections and an equaliser valve. For use in power plants. |
Details |